站内搜索
|
详细信息 Product Name: Pid Dual Row 3-Ledtemperature Controller (XMTD-618) Model NO.: XMTD-618 Display Type: LED Certification: RoHS, UL, CE, ISO Customized: Customized Size: 72*72 Control Type: Digital Type: Temperature Controller Control Method: Electronic Type Usage: Temperature Control Trademark: CJ Transport Package: 1PCS/Box Specification: ISO 9001: 2008 Others Origin: China HS Code: 9032900090 Product Description SpecificationsTemperature controllerOn/offPID controlTemperature meter are dual row 3-LED displayInput: CU50; PT100; J; E; K; TXMT*608 series intelligent temperature controller, is double row 3-LED display and include on/off, PID control, including with parameter of self-setting function. This temperature meter respectively display temperature measurement value (PV) and temperature set value (SV) under normal mode; When it is time temperature control, respectively display temperature measurement value (PV) and running time count down (SV), and also provide kinds of time control method selection; The controller can input kinds of signal which are used interchangeably, it adopt ON/OFFP=0PID control, allowing an easy parameter setting and convenient inputting, is widely used over temperature automatic control systems of machinerychemicalceramicslight industrialmetallurgypetrifaction and heat treatment and so on.Main technical Indexes1, Measurement deviation: ± 0.5%F· S± 1B, Cold end compensating deviation≤ ± 2C2, Input(can be selected): CU50(-50~150), PT100(-199~600), K(-30~999),E(-30~700), J(-30~900), T(199~400)3, Relay output contact capacity: AC220V 5A(resistance load)Period 2~120s can be adjusted.4, Drivng solid relay signal output: Driving electric current >15m A voltage >9V,Period is 2S5, Power: AC85V~242V, 50/60Hz6, Work environment: Temperature 0~50.0C, relative humidity≤ 85%RH, without corrode and strong electric radiation.Model sense XMT( )-6 ( ) 8 ( ) 1 2 3 4 51:External size and Installation hole(mm)Empty 160×80×90 152×76 A 96×96×90 92×92D 72×72×90 68×68 E 48×96×90 44×92F 96×48×90 92×44 G 48×48×100 44×44S 80×160×90 76×152 B 60×120×90 56×116C 80×120×35 wall set installation2. Operation display method:'6': 3-key gentel push-switch setting, double row digital display, have PID adjustment3. An additional alarm:Blank or '0': indicates no alarm;'1': High limit touch alarm;'2': low limit touch alarm4. Input signal classification: '8' : Input signal can interchange free5. Suffix: None: relay output G: solid state relay outputSeriesCodeNameSetting rangeRemarkEx-FactoryFirstMenu0-Appointed dataDeterminedbyandPress∧or∨for 3 second and set the temperature setting value you need-1ALHigh/Low-limitalarmDeterminedbyand-Random2SCMeasurementdeviation-20.0~20.0Measuring value can be modified through increasing or decreasing this data.03PProportion time0~99.9~200When the P↑,the proportion and differentialfunction↓;If the P↓,the proportion anddifferential function↑When P=0,the meter is ON/OFF control.15.04ICalculus time0~999It's used to adjust static difference. To increse it,the static difference will be reduced, but if it is too high, the static difference will drift instability.2405dDifferential time0~200306tControl period2~120SWhen it leaves factory, SSR is 2s;Relay is 20s.When P=0, it makes no sense.207HyMain control by drop in level0.1~50.0It only controls at ON/OFF1.08AtParameter setting itself/OFF_shut itself function ;ON_open itself functionSelect ' ON'only can adjust for one time,and then turn back to 'OFF 'OFF9LocElectronicslock0~50Loc=0 all the parameter can be revisedLoc=1 only the appointed data can be revised0SecondMenu10LocElectronicslock0~50idem011SnInput type-CU50PT100KEJ(T;K12dILSet lower limitdIL≤dIHCU50(-50~150)PT100(-80~600)K(-30~999)E(-30~700)J(-30~900)T(199~400)013dIHSet upper limit40014PFFilt modulus0~50It is the software filter constant of measurement sampling.The constant ↑,the measurement antijamming capability↑,but the measurement speed and system response time ↓2015COLSystem functionchoiceON/OFFON:positive control(cooling control)OFF:reverse control(heating control)OFF
|